Description
A digital combo set.<br />
Available in four modifications.<br />
A digital combo set for maintenance and repair of carrier channels and data transmission equipment of information structures.<br />
Functions
Sine-wave generator
Broadband rms voltmeter
Narrowband (selective) rms voltmeter
Frequency meter
Waveform monitor
Spectrum analyzer
Measured parameters
measurement of root-mean-square AC voltage and frequency of single-ended or differential signals
generation of sine-waves
visual examination of freeform signals
signal spectrum analysis
Standard scope of supply
Digital combo set SVG-5
AC220/12 V power adapter
Set of cables
Instrument certificate, testing guidance, operation manual
Carrying case
Technical characteristics
1. Sine-wave generator
Frequency range30 Hz … 2.5 MHz<br />
Step1 Hz<br />
Frequency setting error±1 · 10-5 % ±1Hz<br />
Output signal level at characteristic impedance termination-50 dB… +14 dB<br />
(2.5 mV … 3.88 V)<br />
Output signal level setting step0.1 dB (0.01 V)<br />
Single-ended output impedance50 Ohm (75 Ohm)<br />
Differential output impedance100 Ohm (150 Ohm)<br />
Level setting relative error±5 %
2. Broadband rms voltmeter
Measured signal level range-50 dB … +40 dB<br />
(2.5 mV … 77.5 V)<br />
Input signal frequency range30 Hz … 2.5 MHz<br />
Level measurement relative error±5 %<br />
Single-ended input impedance50 Ohm, 75 Ohm, 100 Ohm, 600 Ohm, 1 MOhm<br />
Differential input impedance100 Ohm, 150 Ohm, 200 Ohm, 1200 Ohm, 1 MOhm
3. Narrowband (selective) rms voltmeter
Measured signal level range-50 dB… +40 dB (2.5 mV … 77.5 V)<br />
Input signal frequency range30 Hz … 2.5 MHz<br />
Level measurement relative error±5 %<br />
Frequency bandwidth at -3 dB40 Hz, 100 Hz, 1.7 kHz<br />
Single-ended input impedance50 Ohm, 75 Ohm, 100 Ohm, 600 Ohm, 1 MOhm<br />
Differential input impedance100 Ohm, 150 Ohm, 200 Ohm, 1200 Ohm, 1 MOhm
4. Frequency meter
Measured frequency range30 Hz … 2.5 MHz<br />
Measured signal level range77.5 mV…77.5 V<br />
Level measurement relative error±1 · 10-5 % ±1 Hz
5. Wave form monitor
Amplitude scanning range10 µV…100 V<br />
Time scanning range5 ns… 5 s<br />
Input signal frequency range30 Hz … 2.5 MHz<br />
Number of channels1
6. Spectrum analyzer
Maximum frequency4 MHz<br />
Scale division interval5 kHz, 50 kHz, 400 kHz<br />
Instantaneous dynamic range60 dB<br />
Full dynamic range80 dB
Real-time clock
10 settings in memory for each mode
Saves 50 previous measurements in voltmeter mode
Continuous work time 8 hours
Dimensions: 360 × 380 × 140 mm
- Frequency meter
- device for radio stations
- transmitter test load meter
- amplitude modulation of a radio signal
- distortion factor meter
- radio set for handheld transceivers
- AC voltmeter
- measurement of level of a signal
- Sine-wave generator
- broadband r
Production Capacity:
Not informed
Delivery Timeframe:
Not informed
Incoterms:
Not informedPackaging Details:
Not informed
More about
Kontour ETC
10-50
Employees
Not informed
Not informed
Year
Established
Business type
- Industry / Manufacturer
Keywords
- Frequency meter
- device for radio stations
- transmitter test load meter
- amplitude modulation of a radio signal
- distortion factor meter
- radio set for handheld transceivers
- AC voltmeter
- measurement of level of a signal
- Sine-wave generator
- broadband rms voltmeter
- narrowband rms voltmeter
- frequency meter
- waveform monitor
- spectrum analyzer
- digital combo set
- selective rms voltmeter
- test
- tester
- testing
- set
- communication
- radio communication
- radio communication tester
- adjustment
- re Ver Mais
Contact and location
- Olga Leshkova
- +7 383 xxxxxxxx
- Novosibirsk / Novosibirsk | Russian Federation